Accessories
Sampling devices
Description
Nutrisafe 2 sampling straw is a device connected to a Nutrisafe 2 syringe for drug sampling (code 817.052) or to fill the syringe with milk / milk… Read more
Product highlights
In order to respond to the specific needs of neonatology, Vygon promotes an enteral range dedicated to neonates and newborns, called nutrisafe2. This range is compliant with ISO 80369-1.
Safe
Specially designed for neonatal patients, nutrisafe2 is a unique safe enteral feeding system incompatible with Luer and other small-bore connectors in accordance with ISO 80369-1 requirements. The risk of misconnection is minimized, and the patient safety is increased.
The lockable system provides additional security. Accidental disconnection is practically impossible, ensuring precious nutrients are received.
Clean
Feeding tube must not create extra risk to neonates by introducing bacteria into their digestive tract.
Studies have shown that the design of ENFit™ comes with the need of setting up a cleaning procedure, and that even followed thoroughly, only 31% of connectors were off residues. (1)
nutrisafe2 is, by design, less prompt to keep residues. Indeed, nutrisafe2 connectors have a less threaded interior to sequester milk or medication and is much smaller. (2)
(1) Lyman, B., Rahe, K. L., Keeler, D., Sherman, A. K., & Abdelhadi, R. A. (2020). Randomized Controlled Trial Assessing the Effectiveness of Two Cleaning Regimens for ENFit® Connectors. Medsurg Nursing, 29(6), 401-406
(2) Risks for Neonates Due to ENFitTM von Dr. Keliana O’Mara.; 2022. Accessed August 4, 2022.
Accurate
Dose accuracy is of great importance in the NICU wards, especially for critical drugs administration. For example, the morphine dose for a preterm baby can start at 0.03 ml. Studies have shown that because of fluid displacement there is an overdosing risk with the syringes.
Description
Nutrisafe 2 sampling straw is a device connected to a Nutrisafe 2 syringe for drug sampling (code 817.052) or to fill the syringe with milk / milk formula (other codes).Some sampling devices have a smaller bore (internal Ø1.5mm or 2.0mm) for non viscous solutions, other sampling devices have a larger bore (internal Ø3.0mm) for fortified milk.
References and Features
Cannula | Cap | Compatibility | Spike | Packaging | |||||
---|---|---|---|---|---|---|---|---|---|
Favourites | Code | Length cm | Int. Ø mm | Ext. Ø mm | Ø mm | Ø flacon mm | Priming volume ml | Units/Box | Units/Case |
817.052-100 | 5 | 1.2 | 2.0 | - | - | - | 100 | 1800 | |
817.152 | 15 | 2.0 | 3.3 | - | - | - | 50 | 900 | |
817.153 | 15 | 3.0 | 4.2 | - | - | - | 50 | 900 | |
817.202 | 20 | 2.0 | 3.3 | - | - | - | 50 | 900 | |
817.203 | 20 | 3.0 | 4.2 | - | - | - | 50 | 900 | |
817.302 | 30 | 3.0 | 4.2 | - | - | - | 50 | 600 | |
817.502 | 50 | 2.0 | 3.3 | - | - | - | 20 | 240 | |
820.18 | - | - | - | 18 | - | - | 20 | 480 | |
820.20 | - | - | - | 20 | - | - | 20 | 480 | |
820.22 | - | - | - | 22 | - | - | 20 | 480 | |
820.28 | - | - | - | 28 | - | - | 20 | 480 | |
821.012 | - | - | - | - | 14 | 0.12 | 50 | 400 | |
821.022 | - | - | - | - | 20 | 0.17 | 25 | 200 |
Additional information
-
Contains Latex No
-
Contains animal product No
-
Pyrogen-free No